Investment Project for Phasing out CFCs at FAEM S.A.
Project / Program Summary
I. Basic data
|
II. Project / programme description
- Objectives
To eliminate the use of ODS (ozone depleting substances) as CFC 11 and CFC 12 in the production of domestic refrigerators, freezers and cold rooms insulation at FAEM through conversion to the use of HFC 134a as refrigerant for the refrigerators and freezers and cyclopentane as blowing agent for the polyurethane insulation foam. - Activities / contents
- Procurement of new machinery and equipment
- Rebuilding and partially replacing of presently used equipment, such as vacuum pumps
- Redesign, reconstruction, prototype manufacturing and testing of refrigerators and freezers
- Installation, commissioning, training of national personnel in Europe and on-the-job training, trial operation and start-up.
- Outcomes / impacts
Converted production lines to non-CFC using one, producing CFC-free refrigerators and freezers. - Features in line with the Agenda for Action
environment management (ozone layer protection), compliance with international conventions and global agreements and protocols
III. Contact point:
Mr. S.M. Si Ahmed, Acting Director, Montreal Protocol Branch
Sectoral Support and Environmental Sustainability Division, UNIDO,
P.O. Box 400, A-1400 Vienna, Austria, Tel: 43-1-21131 3782, Fax: 43-1-21131 6804